Technology&Platforms
ultrafleX

 

The ultrafleXtreme incorporates next-generation MALDI-TOF and TOF/TOF technology:

• The innovative smartbeam-II™ laser enables ultra-high data acquisition speed in both MS and MS/MS at full systems performance.  The well-established proprietary smartbeam laser provides unprecedented analytical and matrix flexibility in workflows from protein tissue imaging, intact proteins analysis, biologics or oligo QC, to LC-MALDI proteomics - all fully enabled at 1~1000 Hz repetition rates.

• Bruker/’s patented smartbeam technology is already widely accepted as the most viable MALDI imaging laser technology. The ultrafleXtreme now enables laser focus diameters down to 10 µm for high spatial resolution imaging without pixel overlap. Importantly, outstanding spectral quality and signal intensity are maintained at even the smallest laser beam diameters.

• Broadband mass resolving power up to 40,000 enables precision proteomics via Bruker’s unique PAN™ technology for highest mass resolution across a very broad mass range, not just at a selected optimum.

• The novel FlashDetector™ combined with a new 4 GHz digitizer and latest advances in electronics provide unmatched mass resolving power up to 40,000 and 1 ppm mass accuracy for highest confidence.

• The novel and unique laser-irradiation self-cleaning MALDI Perpetual™ Ion Source ensures robust, long-term and highest-performance operation. Very long MALDI laser lifetime in combination with automated source cleaning in just minutes leads to high uptime and low maintenance costs.

• Latest TOF/TOF technology: The high efficiency and sensitivity of the LID-LIFT process delivers MS/MS spectra with nominal mass resolution for peptides. Typically, full MS/MS data sets can be acquired from low fmol levels within seconds. The Bruker bioinformatic software is perfectly adapted to analyze and visualize the match between the raw spectra and annotated peptide and protein structures. 

 

High confidence in protein ID

 

 Schematic representation ultrafleXtreme

 

 

 

 

 Prespotted AnchorChip target in MTP format

 

 

 mass accuracy < 1 ppm and superb resolving power simultaneously across the entire Proteomics mass range due to its PAN technology

 

Identification of biomarkers with LC-MALDI and PCA
 
More information please contact,
Phone: +86 13670280080

  News
  Related Information
·LTQ Orbitrap Velos
·Q TRAP® 5500
   |   BMC   |   Legal   |   Site Map   |   Privacy   |   Contact Copyright © 1999-2010 BGI